Pedego error 35: Motor Phase Error

High severity Service soon

Can I ride home with this error?

Stop riding. Motor may not run properly; do not ride under power until checked.

What it means

Can disrupt motor performance and may prevent the bike from functioning.

Likely causes

  • Poor or loose connection between controller and motor cable
  • Damaged motor cable or wiring
  • Faulty motor phase wiring inside the motor

Symptoms

  • Disrupted motor performance

How to fix it

  1. Make sure the motor cable is secure at controller and motor; re-seat
  2. Check the cable for cuts, fraying, corrosion; replace if damaged
  3. Replace the motor if it has an internal wiring issue
  4. Replace the controller if the error persists
Still showing 35? The RideFixer app finds bike shops near you, so you know where to take it.

How urgent is it?

Have motor wiring diagnosed.