Hyena eSystem (Trek service help) error code
Hyena eSystem (Trek service help) error 74: Battery discharging temperature error
Medium severity Service soon
Can I ride home with this error?
Ride with caution. Stop and let it cool.
What it means
The battery is outside its normal temperature range while giving power.
Likely causes
- Battery overheating during use
- High outside temperature
- Long uphill ride with a heavy load
- Faulty battery management system
Symptoms
- Error 74
- Assist stops
How to fix it
- Stop, keep the bike still and turn it off.
- Move it to a cool, well-ventilated place for at least 10 minutes.
- Restart and check the error.
- If it stays, try a spare battery.
- Contact Trek Customer Care or the Hyena Service Center.
How urgent is it?
Check it if it repeats in mild weather.
Applies to