RideFixer

Hyena eSystem (Trek service help) error code

Hyena eSystem (Trek service help) error 133: Main battery communication failure

Medium severity Service soon

Can I ride home with this error?

Ride with caution. The extender battery may not supply power; the main battery may still work.

What it means

The extender and main batteries are not talking to each other.

Likely causes

  • Extender battery communication system malfunction

Symptoms

  • Error 133

How to fix it

  1. Power off the bike and make sure the connection cable between the extender battery and the bike is firmly plugged in.
  2. Restart the bike.
  3. Detach the extender battery, power on, and deal with any other error codes first.
  4. Charge the extender battery on its own for at least 30 minutes, reattach it and restart.
  5. Replace the connection cable.
  6. Replace the main battery's charging socket cable.
  7. Replace the extender battery.
  8. Replace the main battery.
  9. Do not swap the extender battery with one from another bike, or test with a new one on this bike, because Trek says that can cause misdiagnosis and extra error codes.
  10. Contact Trek Customer Care or the Hyena Service Center.
Still showing 133? The RideFixer app finds bike shops near you, so you know where to take it.

How urgent is it?

Have it checked by a dealer.

Applies to

Did this help?

More Hyena eSystem (Trek service help) codes