E08 - Motor Phase Fault
Motor phase wire signal is abnormal.
High severity
Stop rideability
Immediate urgency
What it means
Power wires between controller and motor may be shorted or disconnected.
Common causes
- Loose phase connector
- Burned wire
- Controller MOSFET fault
Symptoms
- Motor vibrates
- No rotation
- Controller gets hot
How to fix it
- Stop riding
- Inspect phase wires
- Check connectors
- Service controller/motor